22 Westbrook Drive, Morganville, N.J. 07751 Tel: 201.601.5700 Fax: 201.601.4743 Email: unitedblower@yahoo.com |
UNITED TYPE "P" Blower Exhauster with direct connected motors. |
 |
Prevents metal fume fever in welding operations by pulling away the smoke and fumes from the breathing zone of the worker by means of our Type "P" Exhauster. |
They can be used for blowing and exhausting air, dust. light shaving or other materials, from power presses, hammers, high speed grinders, as well as grinding and buffing wheels. |
Also cooling-high temperature Electronic Tubes such as used in Sealing Machines. |
Capacities listed below are based on accurate tests over entire operating range shown. |
These blowers can also be furnished with polyphase or explosion proof motors at slight increase in price. |
|
Standard Blowers are built with cast aluminum casing, and all aluminum blower wheels. |
CFM AIR DELIVERY AT 3450 RPM |
| Fan NO. |
H.P. |
FREE DEL |
SP 1" |
SP 2" |
SP 3" |
SP 4" |
SP 5" |
SP 6" |
SP 7" |
|
|
| 6P |
1/4 |
350 |
320 |
265 |
240 |
200 |
-- |
-- |
-- |
Specify Voltage When Ordering |
| 7P1 |
1/3 |
650 |
550 |
400 |
300 |
250 |
-- |
-- |
-- |
| 7P2 |
1/2 |
800 |
700 |
625 |
575 |
450 |
375 |
-- |
-- |
| 8P1 |
1 |
1020 |
980 |
930 |
870 |
800 |
730 |
640 |
530 |
| 8P2 |
2 |
1230 |
1110 |
1140 |
1080 |
1010 |
940 |
850 |
740 |
| 8P3 |
3 |
1320 |
1280 |
1230 |
1170 |
1100 |
1030 |
940 |
830 |
CAUTION: Must not be used where static pressure is less than shown in table. Severe motor overload will result. Motor overload protection, closely matched to motor full-load current, is highly recommended. |
|
| United Portable Ventilating Sets Dimensions |
| Fan NO. |
A |
B |
C |
D |
E |
F |
G |
H |
K |
L |
Approx. Ship. Weight |
|
| 6P |
3 |
4 |
12 |
11¾ |
13¼ |
10½ |
5¾ |
1 |
4 |
3/8 |
75 |
| 7P1 |
5 |
5 |
15 |
13½ |
14 |
11½ |
5¾ |
1 |
4 |
3/8 |
95 |
| 7P2 |
5 |
5 |
15 |
13½ |
15 |
11½ |
5¾ |
1 |
4 |
3/8 |
100 |
| 8P1-2-3 |
5 |
7 |
19½ |
18 |
20½ |
16 |
9 |
1 |
5 1/16 |
7/16 |
135 |
|
 |
|